Thunderbolt4 mesh network

Complete (ish) Thunderbolt 4 + Ceph Guide: Setup for Proxmox VE 9 BETA STABLE

Acknowledgments

This builds upon excellent foundational work by @scyto.

Key contributions from @scyto's work:

  • TB4 hardware detection and kernel module strategies
  • Systemd networking and udev automation techniques
  • MTU optimization and performance tuning approaches

Overview:

This guide provides a step-by-step, tested (lightly) for building a high-performance Thunderbolt 4 + Ceph cluster on Proxmox VE 9 beta.

Lab Results:

  • TB4 Mesh Performance: Sub-millisecond latency, 65520 MTU, full mesh connectivity
  • Ceph Performance: 1,300+ MB/s write, 1,760+ MB/s read with optimizations
  • Reliability: 0% packet loss, automatic failover, persistent configuration
  • Integration: Full Proxmox GUI visibility and management

Hardware Environment:

  • Nodes: 3x systems with dual TB4 ports (tested on MS01 mini-PCs)
  • Memory: 64GB RAM per node (optimal for high-performance Ceph)
  • CPU: 13th Gen Intel (or equivalent high-performance processors)
  • Storage: NVMe drives for Ceph OSDs
  • Network: TB4 mesh (10.100.0.0/24) + management (10.11.12.0/24)

Software Stack:

  • Proxmox VE: 9.0 beta with native SDN OpenFabric support
  • Ceph: Nautilus with BlueStore, LZ4 compression, 2:1 replication
  • OpenFabric: IPv4-only mesh routing for simplicity and performance

Prerequisites: What You Need

Physical Requirements

  • 3 nodes minimum: Each with dual TB4 ports (tested with MS01 mini-PCs)
  • TB4 cables: Quality TB4 cables for mesh connectivity
  • Ring topology: Physical connections n2→n3→n4→n2 (or similar mesh pattern)
  • Management network: Standard Ethernet for initial setup and management

Software Requirements

  • Proxmox VE 9.0 beta (test repository)
  • SSH root access to all nodes
  • Basic Linux networking knowledge
  • Patience: TB4 mesh setup requires careful attention to detail!

Network Planning

  • Management network: 10.11.12.0/24 (adjust to your environment)
  • TB4 cluster network: 10.100.0.0/24 (for Ceph cluster traffic)
  • Router IDs: 10.100.0.12 (n2), 10.100.0.13 (n3), 10.100.0.14 (n4)

Phase 1: Thunderbolt Foundation Setup

Step 1: Prepare All Nodes

Critical: Perform these steps on ALL mesh nodes (n2, n3, n4).

Load TB4 kernel modules:

# Execute on each node:
for node in n2 n3 n4; do
  ssh $node "echo 'thunderbolt' >> /etc/modules"
  ssh $node "echo 'thunderbolt-net' >> /etc/modules"  
  ssh $node "modprobe thunderbolt && modprobe thunderbolt-net"
done

Verify modules loaded:

for node in n2 n3 n4; do
  echo "=== TB4 modules on $node ==="
  ssh $node "lsmod | grep thunderbolt"
done

Expected output: Both thunderbolt and thunderbolt_net modules present.

Step 2: Identify TB4 Hardware

Find TB4 controllers and interfaces:

for node in n2 n3 n4; do
  echo "=== TB4 hardware on $node ==="
  ssh $node "lspci | grep -i thunderbolt"
  ssh $node "ip link show | grep -E '(en0[5-9]|thunderbolt)'"
done

Expected: TB4 PCI controllers detected, TB4 network interfaces visible.

Step 3: Create Systemd Link Files

Critical: Create interface renaming rules based on PCI paths for consistent naming.

For all nodes (n2, n3, n4):

# Create systemd link files for TB4 interface renaming:
for node in n2 n3 n4; do
  ssh $node "cat > /etc/systemd/network/00-thunderbolt0.link << 'EOF'
[Match]
Path=pci-0000:00:0d.2
Driver=thunderbolt-net

[Link]
MACAddressPolicy=none
Name=en05
EOF"

  ssh $node "cat > /etc/systemd/network/00-thunderbolt1.link << 'EOF'
[Match]
Path=pci-0000:00:0d.3
Driver=thunderbolt-net

[Link]
MACAddressPolicy=none
Name=en06
EOF"
done

Note: Adjust PCI paths if different on your hardware (check with lspci | grep -i thunderbolt)

Step 4: Configure Network Interfaces

Add TB4 interfaces to network configuration with optimal settings:

# Configure TB4 interfaces on all nodes:
for node in n2 n3 n4; do
  ssh $node "cat >> /etc/network/interfaces << 'EOF'

auto en05
iface en05 inet manual
    mtu 65520

auto en06
iface en06 inet manual
    mtu 65520
EOF"
done

Step 5: Enable systemd-networkd

Required for systemd link files to work:

# Enable and start systemd-networkd on all nodes:
for node in n2 n3 n4; do
  ssh $node "systemctl enable systemd-networkd && systemctl start systemd-networkd"
done

Step 6: Create Udev Rules and Scripts

Automation for reliable interface bringup on cable insertion:

Create udev rules:

for node in n2 n3 n4; do
  ssh $node "cat > /etc/udev/rules.d/10-tb-en.rules << 'EOF'
ACTION==\"add|move\", SUBSYSTEM==\"net\", KERNEL==\"en05\", RUN+=\"/usr/local/bin/pve-en05.sh\"
ACTION==\"add|move\", SUBSYSTEM==\"net\", KERNEL==\"en06\", RUN+=\"/usr/local/bin/pve-en06.sh\"
EOF"
done

Create interface bringup scripts:

# Create en05 bringup script for all nodes:
for node in n2 n3 n4; do
  ssh $node "cat > /usr/local/bin/pve-en05.sh << 'EOF'
#!/bin/bash
LOGFILE=\"/tmp/udev-debug.log\"
echo \"\$(date): en05 bringup triggered\" >> \"\$LOGFILE\"
for i in {1..5}; do
    {
        ip link set en05 up mtu 65520
        echo \"\$(date): en05 up successful on attempt \$i\" >> \"\$LOGFILE\"
        break
    } || {
        echo \"\$(date): Attempt \$i failed, retrying in 3 seconds...\" >> \"\$LOGFILE\"
        sleep 3
    }
done
EOF"
  ssh $node "chmod +x /usr/local/bin/pve-en05.sh"
done

# Create en06 bringup script for all nodes:
for node in n2 n3 n4; do
  ssh $node "cat > /usr/local/bin/pve-en06.sh << 'EOF'
#!/bin/bash
LOGFILE=\"/tmp/udev-debug.log\"
echo \"\$(date): en06 bringup triggered\" >> \"\$LOGFILE\"
for i in {1..5}; do
    {
        ip link set en06 up mtu 65520
        echo \"\$(date): en06 up successful on attempt \$i\" >> \"\$LOGFILE\"
        break
    } || {
        echo \"\$(date): Attempt \$i failed, retrying in 3 seconds...\" >> \"\$LOGFILE\"
        sleep 3
    }
done
EOF"
  ssh $node "chmod +x /usr/local/bin/pve-en06.sh"
done

Step 7: Update Initramfs and Reboot

Apply all TB4 configuration changes:

# Update initramfs on all nodes:
for node in n2 n3 n4; do
  ssh $node "update-initramfs -u -k all"
done

# Reboot all nodes to apply changes:
echo "Rebooting all nodes - wait for them to come back online..."
for node in n2 n3 n4; do
  ssh $node "reboot"
done

# Wait and verify after reboot:
echo "Waiting 60 seconds for nodes to reboot..."
sleep 60

# Verify TB4 interfaces after reboot:
for node in n2 n3 n4; do
  echo "=== TB4 interfaces on $node after reboot ==="
  ssh $node "ip link show | grep -E '(en05|en06)'"
done

Expected result: TB4 interfaces should be named en05 and en06 with proper MTU settings.

Step 8: Enable IPv4 Forwarding

Essential: TB4 mesh requires IPv4 forwarding for OpenFabric routing.

# Configure IPv4 forwarding on all nodes:
for node in n2 n3 n4; do
  ssh $node "echo 'net.ipv4.ip_forward=1' >> /etc/sysctl.conf"
  ssh $node "sysctl -p"
done

Verify forwarding enabled:

for node in n2 n3 n4; do
  echo "=== IPv4 forwarding on $node ==="
  ssh $node "sysctl net.ipv4.ip_forward"
done

Expected: net.ipv4.ip_forward = 1 on all nodes.

Step 9: Create Systemd Service for Boot Reliability

Ensure TB4 interfaces come up automatically on boot:

Create systemd service:

for node in n2 n3 n4; do
  ssh $node "cat > /etc/systemd/system/thunderbolt-interfaces.service << 'EOF'
[Unit]
Description=Configure Thunderbolt Network Interfaces
After=network.target thunderbolt.service
Wants=network.target

[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/local/bin/thunderbolt-startup.sh

[Install]
WantedBy=multi-user.target
EOF"
done

Create startup script:

for node in n2 n3 n4; do
  ssh $node "cat > /usr/local/bin/thunderbolt-startup.sh << 'EOF'
#!/bin/bash
# Thunderbolt interface startup script
LOGFILE=\"/var/log/thunderbolt-startup.log\"

echo \"\$(date): Starting Thunderbolt interface configuration\" >> \"\$LOGFILE\"

# Wait up to 30 seconds for interfaces to appear
for i in {1..30}; do
    if ip link show en05 &>/dev/null && ip link show en06 &>/dev/null; then
        echo \"\$(date): Thunderbolt interfaces found\" >> \"\$LOGFILE\"
        break
    fi
    echo \"\$(date): Waiting for Thunderbolt interfaces... (\$i/30)\" >> \"\$LOGFILE\"
    sleep 1
done

# Configure interfaces if they exist
if ip link show en05 &>/dev/null; then
    /usr/local/bin/pve-en05.sh
    echo \"\$(date): en05 configured\" >> \"\$LOGFILE\"
fi

if ip link show en06 &>/dev/null; then
    /usr/local/bin/pve-en06.sh
    echo \"\$(date): en06 configured\" >> \"\$LOGFILE\"
fi

echo \"\$(date): Thunderbolt configuration completed\" >> \"\$LOGFILE\"
EOF"
  ssh $node "chmod +x /usr/local/bin/thunderbolt-startup.sh"
done

Enable the service:

for node in n2 n3 n4; do
  ssh $node "systemctl daemon-reload"
  ssh $node "systemctl enable thunderbolt-interfaces.service"
done

Note: This service ensures TB4 interfaces come up even if udev rules fail to trigger on boot.

Phase 2: Proxmox SDN Configuration

Step 4: Create OpenFabric Fabric in GUI

Location: Datacenter → SDN → Fabrics

  1. Click: "Add Fabric" → "OpenFabric"

  2. Configure in the dialog:

    • Name: tb4
    • IPv4 Prefix: 10.100.0.0/24
    • IPv6 Prefix: (leave empty for IPv4-only)
    • Hello Interval: 3 (default)
    • CSNP Interval: 10 (default)
  3. Click: "OK"

Expected result: You should see a fabric named tb4 with Protocol OpenFabric and IPv4 10.100.0.0/24

image

Step 5: Add Nodes to Fabric

Still in: Datacenter → SDN → Fabrics → (select tb4 fabric)

  1. Click: "Add Node"

  2. Configure for n2:

    • Node: n2
    • IPv4: 10.100.0.12
    • IPv6: (leave empty)
    • Interfaces: Select en05 and en06 from the interface list
  3. Click: "OK"

  4. Repeat for n3: IPv4: 10.100.0.13, interfaces: en05, en06

  5. Repeat for n4: IPv4: 10.100.0.14, interfaces: en05, en06

Expected result: You should see all 3 nodes listed under the fabric with their IPv4 addresses and interfaces (en05, en06 for each)

Important: You need to manually configure /30 point-to-point addresses on the en05 and en06 interfaces to create mesh connectivity. Example addressing scheme:

  • n2: en05: 10.100.0.1/30, en06: 10.100.0.5/30
  • n3: en05: 10.100.0.9/30, en06: 10.100.0.13/30
  • n4: en05: 10.100.0.17/30, en06: 10.100.0.21/30

These /30 subnets allow each interface to connect to exactly one other interface in the mesh topology. Configure these addresses in the Proxmox network interface settings for each node.

image

Step 6: Apply SDN Configuration

Critical: This activates the mesh - nothing works until you apply!

In GUI: Datacenter → SDN → "Apply" (button in top toolbar)

Expected result: Status table shows all nodes with "OK" status like this:

SDN     Node    Status
localnet... n3   OK
localnet... n1   OK  
localnet... n4   OK
localnet... n2   OK
image

Step 7: Start FRR Service

Critical: OpenFabric routing requires FRR (Free Range Routing) to be running.

# Start and enable FRR on all mesh nodes:
for node in n2 n3 n4; do
  ssh $node "systemctl start frr && systemctl enable frr"
done

Verify FRR is running:

for node in n2 n3 n4; do
  echo "=== FRR status on $node ==="
  ssh $node "systemctl status frr | grep Active"
done

Expected output:

=== FRR status on n2 ===
     Active: active (running) since Mon 2025-01-27 20:15:23 EST; 2h ago
=== FRR status on n3 ===
     Active: active (running) since Mon 2025-01-27 20:15:25 EST; 2h ago
=== FRR status on n4 ===
     Active: active (running) since Mon 2025-01-27 20:15:27 EST; 2h ago

Command-line verification:

# Check SDN services on all nodes:
for node in n2 n3 n4; do
  echo "=== SDN status on $node ==="
  ssh $node "systemctl status frr | grep Active"
done

Expected output:

=== SDN status on n2 ===
     Active: active (running) since Mon 2025-01-27 20:15:23 EST; 2h ago
=== SDN status on n3 ===
     Active: active (running) since Mon 2025-01-27 20:15:25 EST; 2h ago
=== SDN status on n4 ===
     Active: active (running) since Mon 2025-01-27 20:15:27 EST; 2h ago

Phase 3: Mesh Verification and Testing

Step 8: Verify Interface Configuration

Check TB4 interfaces are up with correct settings:

for node in n2 n3 n4; do
  echo "=== TB4 interfaces on $node ==="
  ssh $node "ip addr show | grep -E '(en05|en06|10\.100\.0\.)'"
done

Expected output example (n2):

=== TB4 interfaces on n2 ===
    inet 10.100.0.12/32 scope global dummy_tb4
11: en05: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
    inet 10.100.0.1/30 scope global en05
12: en06: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
    inet 10.100.0.5/30 scope global en06

What this shows:

  • Router ID address: 10.100.0.12/32 on dummy_tb4 interface
  • TB4 interfaces UP: en05 and en06 with state UP
  • Jumbo frames: mtu 65520 on both interfaces
  • Point-to-point addresses: /30 subnets for mesh connectivity

Step 9: Test OpenFabric Mesh Connectivity

Critical test: Verify full mesh communication works.

# Test router ID connectivity (should be sub-millisecond):
for target in 10.100.0.12 10.100.0.13 10.100.0.14; do
  echo "=== Testing connectivity to $target ==="
  ping -c 3 $target
done

Expected output:

=== Testing connectivity to 10.100.0.12 ===
PING 10.100.0.12 (10.100.0.12) 56(84) bytes of data.
64 bytes from 10.100.0.12: icmp_seq=1 ttl=64 time=0.618 ms
64 bytes from 10.100.0.12: icmp_seq=2 ttl=64 time=0.582 ms
64 bytes from 10.100.0.12: icmp_seq=3 ttl=64 time=0.595 ms
--- 10.100.0.12 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2003ms

=== Testing connectivity to 10.100.0.13 ===
PING 10.100.0.13 (10.100.0.13) 56(84) bytes of data.
64 bytes from 10.100.0.13: icmp_seq=1 ttl=64 time=0.634 ms
64 bytes from 10.100.0.13: icmp_seq=2 ttl=64 time=0.611 ms
64 bytes from 10.100.0.13: icmp_seq=3 ttl=64 time=0.598 ms
--- 10.100.0.13 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2004ms

What to look for:

  • All pings succeed: 3 received, 0% packet loss
  • Sub-millisecond latency: time=0.6xx ms (typical ~0.6ms)
  • No timeouts or errors: Should see response for every packet

If connectivity fails: TB4 interfaces may need manual bring-up after reboot:

# Bring up TB4 interfaces manually:
for node in n2 n3 n4; do
  ssh $node "ip link set en05 up mtu 65520"
  ssh $node "ip link set en06 up mtu 65520"
  ssh $node "ifreload -a"
done

Step 10: Verify Mesh Performance

Test mesh latency and basic throughput:

# Test latency between router IDs:
for node in n2 n3 n4; do
  echo "=== Latency test from $node ==="
  ssh $node "ping -c 5 -i 0.2 10.100.0.12 | tail -1"
  ssh $node "ping -c 5 -i 0.2 10.100.0.13 | tail -1"
  ssh $node "ping -c 5 -i 0.2 10.100.0.14 | tail -1"
done

Expected: Round-trip times under 1ms consistently.

Phase 4: High-Performance Ceph Integration

Step 11: Install Ceph on All Mesh Nodes

Install Ceph packages on all mesh nodes:

# Initialize Ceph on mesh nodes:
for node in n2 n3 n4; do
  echo "=== Installing Ceph on $node ==="
  ssh $node "pveceph install --repository test"
done

Step 12: Create Ceph Directory Structure

Essential: Proper directory structure and ownership:

# Create base Ceph directories with correct ownership:
for node in n2 n3 n4; do
  ssh $node "mkdir -p /var/lib/ceph && chown ceph:ceph /var/lib/ceph"
  ssh $node "mkdir -p /etc/ceph && chown ceph:ceph /etc/ceph"
done

Step 13: Create First Monitor and Manager

CLI Approach:

# Create initial monitor on n2:
ssh n2 "pveceph mon create"

Expected output:

Monitor daemon started successfully on node n2.
Created new cluster with fsid: 12345678-1234-5678-9abc-123456789abc

GUI Approach:

  • Location: n2 node → Ceph → Monitor → "Create"
  • Result: Should show green "Monitor created successfully" message

Verify monitor creation:

ssh n2 "ceph -s"

Expected output:

  cluster:
    id:     12345678-1234-5678-9abc-123456789abc
    health: HEALTH_OK
 
  services:
    mon: 1 daemons, quorum n2 (age 2m)
    mgr: n2(active, since 1m)
    osd: 0 osds: 0 up, 0 in
 
  data:
    pools:   0 pools, 0 pgs
    objects: 0 objects, 0 B
    usage:   0 B used, 0 B / 0 B avail
    pgs:     

Step 14: Configure Network Settings

Set public and cluster networks for optimal TB4 performance:

# Configure Ceph networks:
ssh n2 "ceph config set global public_network 10.11.12.0/24"
ssh n2 "ceph config set global cluster_network 10.100.0.0/24"

# Configure monitor networks:
ssh n2 "ceph config set mon public_network 10.11.12.0/24"
ssh n2 "ceph config set mon cluster_network 10.100.0.0/24"

Step 15: Create Additional Monitors

Create 3-monitor quorum on mesh nodes:

CLI Approach:

# Create monitor on n3:
ssh n3 "pveceph mon create"

# Create monitor on n4:
ssh n4 "pveceph mon create"

Expected output (for each):

Monitor daemon started successfully on node n3.
Monitor daemon started successfully on node n4.

GUI Approach:

  • n3: n3 node → Ceph → Monitor → "Create"
  • n4: n4 node → Ceph → Monitor → "Create"
  • Result: Green success messages on both nodes

Verify 3-monitor quorum:

ssh n2 "ceph quorum_status"

Expected output:

{
    "election_epoch": 3,
    "quorum": [
        0,
        1,
        2
    ],
    "quorum_names": [
        "n2",
        "n3",
        "n4"
    ],
    "quorum_leader_name": "n2",
    "quorum_age": 127,
    "monmap": {
        "epoch": 3,
        "fsid": "12345678-1234-5678-9abc-123456789abc",
        "modified": "2025-01-27T20:15:42.123456Z",
        "created": "2025-01-27T20:10:15.789012Z",
        "min_mon_release_name": "reef",
        "mons": [
            {
                "rank": 0,
                "name": "n2",
                "public_addrs": {
                    "addrvec": [
                        {
                            "type": "v2",
                            "addr": "10.11.12.12:3300"
                        }
                    ]
                }
            }
        ]
    }
}

What to verify:

  • 3 monitors in quorum: "quorum_names": ["n2", "n3", "n4"]
  • All nodes listed: Should see all 3 mesh nodes
  • Leader elected: "quorum_leader_name" should show one of the nodes

Step 16: Create OSDs (2 per Node)

Create high-performance OSDs on NVMe drives:

CLI Approach:

# Create OSDs on n2:
ssh n2 "pveceph osd create /dev/nvme0n1"
ssh n2 "pveceph osd create /dev/nvme1n1"

# Create OSDs on n3:
ssh n3 "pveceph osd create /dev/nvme0n1"
ssh n3 "pveceph osd create /dev/nvme1n1"

# Create OSDs on n4:
ssh n4 "pveceph osd create /dev/nvme0n1"
ssh n4 "pveceph osd create /dev/nvme1n1"

Expected output (for each OSD):

Creating OSD on /dev/nvme0n1
OSD.0 created successfully.
OSD daemon started.

GUI Approach:

  • Location: Each node → Ceph → OSD → "Create: OSD"
  • Select: Choose /dev/nvme0n1 and /dev/nvme1n1 from device list
  • Advanced: Leave DB/WAL settings as default (co-located)
  • Result: Green "OSD created successfully" messages

Verify all OSDs are up:

ssh n2 "ceph osd tree"

Expected output:

ID CLASS WEIGHT  TYPE NAME     STATUS REWEIGHT PRI-AFF 
-1       5.45776 root default                          
-3       1.81959     host n2                           
 0   ssd 0.90979         osd.0     up  1.00000 1.00000 
 1   ssd 0.90979         osd.1     up  1.00000 1.00000 
-5       1.81959     host n3                           
 2   ssd 0.90979         osd.2     up  1.00000 1.00000 
 3   ssd 0.90979         osd.3     up  1.00000 1.00000 
-7       1.81959     host n4                           
 4   ssd 0.90979         osd.4     up  1.00000 1.00000 
 5   ssd 0.90979         osd.5     up  1.00000 1.00000 

What to verify:

  • 6 OSDs total: 2 per mesh node (osd.0-5)
  • All 'up' status: Every OSD shows up in STATUS column
  • Weight 1.00000: All OSDs have full weight (not being rebalanced out)
  • Hosts organized: Each node (n2, n3, n4) shows as separate host with 2 OSDs

Phase 5: High-Performance Optimizations

Step 17: Memory Optimizations (64GB RAM Nodes)

Configure optimal memory usage for high-performance hardware:

# Set OSD memory target to 8GB per OSD (ideal for 64GB nodes):
ssh n2 "ceph config set osd osd_memory_target 8589934592"

# Set BlueStore cache sizes for NVMe performance:
ssh n2 "ceph config set osd bluestore_cache_size_ssd 4294967296"

# Set memory allocation optimizations:
ssh n2 "ceph config set osd osd_memory_cache_min 1073741824"
ssh n2 "ceph config set osd osd_memory_cache_resize_interval 1"

Step 18: CPU and Threading Optimizations (13th Gen Intel)

Optimize for high-performance CPUs:

# Set CPU threading optimizations:
ssh n2 "ceph config set osd osd_op_num_threads_per_shard 2"
ssh n2 "ceph config set osd osd_op_num_shards 8"

# Set BlueStore threading for NVMe:
ssh n2 "ceph config set osd bluestore_sync_submit_transaction false"
ssh n2 "ceph config set osd bluestore_throttle_bytes 268435456"
ssh n2 "ceph config set osd bluestore_throttle_deferred_bytes 134217728"

# Set CPU-specific optimizations:
ssh n2 "ceph config set osd osd_client_message_cap 1000"
ssh n2 "ceph config set osd osd_client_message_size_cap 1073741824"

Step 19: Network Optimizations for TB4 Mesh

Optimize network settings for TB4 high-performance cluster communication:

# Set network optimizations for TB4 mesh (65520 MTU, sub-ms latency):
ssh n2 "ceph config set global ms_tcp_nodelay true"
ssh n2 "ceph config set global ms_tcp_rcvbuf 134217728"
ssh n2 "ceph config set global ms_tcp_prefetch_max_size 65536"

# Set cluster network optimizations for 10.100.0.0/24 TB4 mesh:
ssh n2 "ceph config set global ms_cluster_mode crc"
ssh n2 "ceph config set global ms_async_op_threads 8"
ssh n2 "ceph config set global ms_dispatch_throttle_bytes 1073741824"

# Set heartbeat optimizations for fast TB4 network:
ssh n2 "ceph config set osd osd_heartbeat_interval 6"
ssh n2 "ceph config set osd osd_heartbeat_grace 20"

Step 20: BlueStore and NVMe Optimizations

Configure BlueStore for maximum NVMe and TB4 performance:

# Set BlueStore optimizations for NVMe drives:
ssh n2 "ceph config set osd bluestore_compression_algorithm lz4"
ssh n2 "ceph config set osd bluestore_compression_mode aggressive"
ssh n2 "ceph config set osd bluestore_compression_required_ratio 0.7"

# Set NVMe-specific optimizations:
ssh n2 "ceph config set osd bluestore_cache_trim_interval 200"

# Set WAL and DB optimizations for NVMe:
ssh n2 "ceph config set osd bluestore_block_db_size 5368709120"
ssh n2 "ceph config set osd bluestore_block_wal_size 1073741824"

Step 21: Scrubbing and Maintenance Optimizations

Configure scrubbing for high-performance environment:

# Set scrubbing optimizations:
ssh n2 "ceph config set osd osd_scrub_during_recovery false"
ssh n2 "ceph config set osd osd_scrub_begin_hour 2"
ssh n2 "ceph config set osd osd_scrub_end_hour 6"

# Set deep scrub optimizations:
ssh n2 "ceph config set osd osd_deep_scrub_interval 1209600"
ssh n2 "ceph config set osd osd_scrub_max_interval 1209600"
ssh n2 "ceph config set osd osd_scrub_min_interval 86400"

# Set recovery optimizations for TB4 mesh:
ssh n2 "ceph config set osd osd_recovery_max_active 8"
ssh n2 "ceph config set osd osd_max_backfills 4"
ssh n2 "ceph config set osd osd_recovery_op_priority 1"

Phase 6: Storage Pool Creation and Configuration

Step 22: Create High-Performance Storage Pool

Create optimized storage pool with 2:1 replication ratio:

# Create pool with optimal PG count for 6 OSDs (256 PGs = ~85 PGs per OSD):
ssh n2 "ceph osd pool create cephtb4 256 256"

# Set 2:1 replication ratio (size=2, min_size=1) for test lab:
ssh n2 "ceph osd pool set cephtb4 size 2"
ssh n2 "ceph osd pool set cephtb4 min_size 1"

# Enable RBD application for Proxmox integration:
ssh n2 "ceph osd pool application enable cephtb4 rbd"

Step 23: Verify Cluster Health

Check that cluster is healthy and ready:

ssh n2 "ceph -s"

Expected results:

  • Health: HEALTH_OK (or HEALTH_WARN with minor warnings)
  • OSDs: 6 osds: 6 up, 6 in
  • PGs: All PGs active+clean
  • Pools: cephtb4 pool created and ready

Phase 7: Performance Testing and Validation

Step 24: Test Optimized Cluster Performance

Run comprehensive performance testing to validate optimizations:

# Test write performance with optimized cluster:
ssh n2 "rados -p cephtb4 bench 10 write --no-cleanup -b 4M -t 16"

# Test read performance:
ssh n2 "rados -p cephtb4 bench 10 rand -t 16"

# Clean up test data:
ssh n2 "rados -p cephtb4 cleanup"

Results

Write Performance:

  • Average Bandwidth: 1,294 MB/s
  • Peak Bandwidth: 2,076 MB/s
  • Average IOPS: 323
  • Average Latency: ~48ms

Read Performance:

  • Average Bandwidth: 1,762 MB/s
  • Peak Bandwidth: 2,448 MB/s
  • Average IOPS: 440
  • Average Latency: ~36ms

Step 25: Verify Configuration Database

Check that all optimizations are active in Proxmox GUI:

  1. Navigate: Ceph → Configuration Database
  2. Verify: All optimization settings visible and applied
  3. Check: No configuration errors or warnings

Key optimizations to verify:

  • osd_memory_target: 8589934592 (8GB per OSD)
  • bluestore_cache_size_ssd: 4294967296 (4GB cache)
  • bluestore_compression_algorithm: lz4
  • cluster_network: 10.100.0.0/24 (TB4 mesh)
  • public_network: 10.11.12.0/24

Troubleshooting Common Issues

TB4 Mesh Issues

Problem: TB4 interfaces not coming up after reboot Root Cause: Udev rules may not trigger on boot, scripts may be corrupted

Quick Fix: Manually bring up interfaces:

# Solution: Manually bring up interfaces and reapply SDN config:
for node in n2 n3 n4; do
  ssh $node "ip link set en05 up mtu 65520"
  ssh $node "ip link set en06 up mtu 65520"
  ssh $node "ifreload -a"
done

Permanent Fix: Check systemd service and scripts:

# Verify systemd service is enabled:
for node in n2 n3 n4; do
  ssh $node "systemctl status thunderbolt-interfaces.service"
done

# Check if scripts are corrupted (should be ~13 lines, not 31073):
for node in n2 n3 n4; do
  ssh $node "wc -l /usr/local/bin/pve-en*.sh"
done

# Check for shebang errors:
for node in n2 n3 n4; do
  ssh $node "head -1 /usr/local/bin/*.sh | grep -E 'thunderbolt|pve-en'"
done
# If you see #\!/bin/bash (with backslash), fix it:
for node in n2 n3 n4; do
  ssh $node "sed -i '1s/#\\\\!/#!/' /usr/local/bin/thunderbolt-startup.sh"
  ssh $node "sed -i '1s/#\\\\!/#!/' /usr/local/bin/pve-en05.sh"
  ssh $node "sed -i '1s/#\\\\!/#!/' /usr/local/bin/pve-en06.sh"
done

Problem: Systemd service fails with "Exec format error"

  • Root Cause: Corrupted shebang line in scripts (#!/bin/bash instead of #!/bin/bash)
  • Diagnosis: Check systemctl status thunderbolt-interfaces for exec format errors
  • Solution: Fix shebang lines as shown above, then restart service

Problem: Mesh connectivity fails between some nodes

# Check interface status:
for node in n2 n3 n4; do
  echo "=== $node TB4 status ==="
  ssh $node "ip addr show | grep -E '(en05|en06|10\.100\.0\.)'"
done

# Verify FRR routing service:
for node in n2 n3 n4; do
  ssh $node "systemctl status frr"
done

Ceph Issues

Problem: OSDs going down after creation

  • Root Cause: Usually network connectivity issues (TB4 mesh not working)
  • Solution: Fix TB4 mesh first, then restart OSD services:
# Restart OSD services after fixing mesh:
for node in n2 n3 n4; do
  ssh $node "systemctl restart ceph-osd@*.service"
done

Problem: Ceph cluster shows OSDs down after reboot

  • Symptoms: ceph status shows OSDs down, heartbeat failures in logs
  • Root Cause: TB4 interfaces (Ceph private network) not coming up
  • Solution:
# 1. Bring up TB4 interfaces on all nodes:
for node in n2 n3 n4; do
  ssh $node "/usr/local/bin/pve-en05.sh"
  ssh $node "/usr/local/bin/pve-en06.sh"
done

# 2. Wait for interfaces to stabilize:
sleep 10

# 3. Restart Ceph OSDs:
for node in n2 n3 n4; do
  ssh $node "systemctl restart ceph-osd@*.service"
done

# 4. Monitor recovery:
ssh n2 "watch ceph -s"

Problem: Inactive PGs or slow performance

# Check cluster status:
ssh n2 "ceph -s"

# Verify optimizations are applied:
ssh n2 "ceph config dump | grep -E '(memory_target|cache_size|compression)'"

# Check network binding:
ssh n2 "ceph config get osd cluster_network"
ssh n2 "ceph config get osd public_network"

Problem: Proxmox GUI doesn't show OSDs

  • Root Cause: Usually config database synchronization issues
  • Solution: Restart Ceph monitor services and check GUI again

System-Level Performance Optimizations (Optional)

Additional OS-Level Tuning

For even better performance on high-end hardware:

# Apply on all mesh nodes:
for node in n2 n3 n4; do
  ssh $node "
    # Network tuning:
    echo 'net.core.rmem_max = 268435456' >> /etc/sysctl.conf
    echo 'net.core.wmem_max = 268435456' >> /etc/sysctl.conf
    echo 'net.core.netdev_max_backlog = 30000' >> /etc/sysctl.conf
    
    # Memory tuning:
    echo 'vm.swappiness = 1' >> /etc/sysctl.conf
    echo 'vm.min_free_kbytes = 4194304' >> /etc/sysctl.conf
    
    # Apply settings:
    sysctl -p
  "
done

Changelog

July 30, 2025

  • Added troubleshooting for "Exec format error" caused by corrupted shebang lines
  • Fixed script examples to ensure proper shebang format (#!/bin/bash)
  • Added diagnostic commands for detecting shebang corruption

July 28, 2025

  • Initial complete guide created
  • Integrated TB4 mesh networking with Ceph storage
  • Added systemd service for boot reliability
  • Comprehensive troubleshooting section
@taslabs-net
Copy link
Author

I upgraded 5 nodes today to PVE 9 Stable, everything took a bit, but after about 5 min everything settled down and is working again.

@corvy
Copy link

corvy commented Aug 6, 2025

I upgraded 5 nodes today to PVE 9 Stable, everything took a bit, but after about 5 min everything settled down and is working again.

Did you upgrade from an existing TB + Ceph setup on 8.x to 9? What steps did you take? Did you migrate to the SDN setup?

I am contemplating doing a full reinstall/restore thing personally.

@ssavkar
Copy link

ssavkar commented Aug 6, 2025

I upgraded 5 nodes today to PVE 9 Stable, everything took a bit, but after about 5 min everything settled down and is working again.

Did you upgrade from an existing TB + Ceph setup on 8.x to 9? What steps did you take? Did you migrate to the SDN setup?

I am contemplating doing a full reinstall/restore thing personally.

I have the same question, whether someone has tried to upgrade from 8.x to 9 and whether we have to go through steps there or if somehow the openfabric /SDN configuration comes over from my prior cluster setup with the Scyto implementation?

@michaeleberhardt
Copy link

I just updated my MS-01 Cluster as well. Everything keeps working fine, also Scytos TB implementation.

@ssavkar
Copy link

ssavkar commented Aug 6, 2025

I just updated my MS-01 Cluster as well. Everything keeps working fine, also Scytos TB implementation.

So did you have to make any adjustments or basically the update retained all your network settings, etc? With the new SDN/OpenFabric integration in Proxmox, does that all show up in the GUI even though you had it set up manually through editing files? Just curious.

@michaeleberhardt
Copy link

I just updated my MS-01 Cluster as well. Everything keeps working fine, also Scytos TB implementation.

So did you have to make any adjustments or basically the update retained all your network settings, etc? With the new SDN/OpenFabric integration in Proxmox, does that all show up in the GUI even though you had it set up manually through editing files? Just curious.

I do not see it in the Proxmox GUI, but I am using 2 OVS Bridges, so my config differs a bit from Scytos. But all network settings kept untouched.

@ssavkar
Copy link

ssavkar commented Aug 6, 2025

I just updated my MS-01 Cluster as well. Everything keeps working fine, also Scytos TB implementation.

So did you have to make any adjustments or basically the update retained all your network settings, etc? With the new SDN/OpenFabric integration in Proxmox, does that all show up in the GUI even though you had it set up manually through editing files? Just curious.

I do not see it in the Proxmox GUI, but I am using 2 OVS Bridges, so my config differs a bit from Scytos. But all network settings kept untouched.

I see. I guess part of me wonders if it makes sense to try to from scratch rebuild the OpenFabric piece within the GUI to help with future management sans shell and editors, or if it ain't broken, don't touch it! With my luck when I do the upgrade if I try something like that, Ic could see something breaking!

@corvy
Copy link

corvy commented Aug 6, 2025

You could upgrade first and then migrate to the SDN settings in the GUI, removing the frr settings beforehand of course.

@taslabs-net
Copy link
Author

I upgraded 5 nodes today to PVE 9 Stable, everything took a bit, but after about 5 min everything settled down and is working again.

Did you upgrade from an existing TB + Ceph setup on 8.x to 9? What steps did you take? Did you migrate to the SDN setup?

I am contemplating doing a full reinstall/restore thing personally.

I went from 9 beta to 9 stable.

@flx-666
Copy link

flx-666 commented Aug 8, 2025

Intersting, I just have a few questions however..
I'd ike to have the openfabric setup in sdn for the tb4 network, but I'd like to have specifics vlans for servers (management vlan), users, IoT Guests, Security...
How do I create those vlans, and have the cluster using the vlans from SDN for corosync and management? I would love to have only 1 nic per serrver in the cluster, vlan aware of course, but having the ip for management as part as one of these vlans.
But how to create the proxmox cluster using sdn config before the cluster is created?
I currently have a mix of sdn vlans connected interfaces, and tagged interfaces in my VMs, I'd love to connect to named networks
If you have any suggestion or solutions, I'd be happy to know
Thanks in advance,
Felix

@millercentral
Copy link

millercentral commented Aug 8, 2025

Thanks for writing this up. I am attempting to implement on a 3-node MS-01 cluster. I can see the interfaces and they are all up on all three, but I'm running into a few issues:

  1. On reboot, systemd-networkd-wait-online.service is blocking for almost 3 minutes before failing. Not sure how to debug this.
  2. I configured the SDN fabric in the UI, and started, but there was a warning on each node when I hit apply: WARN: missing 'source /etc/network/interfaces.d/sdn' directive for SDN support!
    3.After applying the SDN and starting FRR, my interfaces do not have IP addresses (ip addr shows the interfaces as up, and they have a autoassigned linklocal ipv6 addr, but no 10.100.0 ipv4 assignment).

EDIT: I realized my /etc/networks/interfaces file did not have the line source /etc/network/interfaces.d/* in it. Adding that back in solved items 2 and 3.

EDIT2: Fixed the networkd-wait-online service by scoping it to just the en05/en06 interfaces.

One question I had on the SDN OpenFabric config: you assigned node n3 as 10.100.0.13, but also assigned en06 on n3 as 10.100.0.13/30 -- is that by design? I used ips 10.100.0.91,10.100.0.92,10.100.0.93 for my nodes to align with their LAN ips, but matched your pattern for the en05 and en05 interface /30 addresses.

The last issue I am having: After reboot, the ports come back up, but the SDN OpenFabric IPv4 addresses are not automatically reassigned/routed. Instead, I have to hit "Apply" again on Datacenter > SDN page...

@Allistah
Copy link

Allistah commented Aug 9, 2025

Hey this is a great guide - thanks for writing it! I'm currently on v8 with Ceph installed and syncing over TB4 with three nodes. Super solid. Many of the steps in this guide I've already got, but I obviously don't have the SDN stuff set up. Looking forward to upgrading to the current version of 9 once things settle a little bit on this guide.

@ratzofftyoya
Copy link

thanks so much for the guide! After the first reboot, I'm seeing the interfaces up with mtu 1500. Any idea why that may be happening? All the config files say MTU 65520.